Quick Contact

    Combi Line - optimal maintenance economy

    The Combi Line filter is based on the same technical principles as a Green Line filter for max. 270°C, and is constructed with special pre-separator plates with cyclone effect but has been improved in this filter. The construction causes a good and optimal spreading of the air to the entire filter area. This ensures a long lifetime of the filter and the filterbags, and therefore an optimal maintenance economy. The Combi Line filter prevents thermal bridges, with its octagonal shape, and is by standard insulated and pre-mounted on the truck, which means much less mounting costs.

    Combi Line - optimal maintenance economy
    Combi Line - optimal maintenance economy

    Application range:

    Smoke and gas from biomass industry boilers, wasteburning, and district heating stations.

    Special features:

    The filter can be delivered with by-pass system. The filter can be delivered with CO2fire exstinguisher.

    Data
    61-18-42
    70-30-80
    152-30-174
    152-35-203
    152-41-237
    152-45-258
    152-50-286
    Area filterbags
    m2
    42
    80
    174
    203
    237
    258
    286
    Number of bags
    61
    70
    152
    152
    152
    152
    152
    Airamount optimal
    m3/h
    1680
    3200
    6880
    8000
    9520
    10320
    11440
    Max. low pressure
    Pa
    15000
    10000
    5000
    5000
    5000
    5000
    5000
    Height x width x Depth
    mm
    5236x2100x2100
    6500x2100x2100
    6460x2865x2865
    6960x2865x2865
    7560x2865x2865
    8060x2865x2865
    8560x2865x2865
    Inlet optional side H x W
    mm
    700 x 400
    700 x 400
    1200 x 600
    1200 x 600
    1200 x 600
    1200 x 600
    1200 x 600
    Outlet optional side H x W
    mm
    250 x 1440
    300 x 600
    300 x 600
    300 x 600
    300 x 600
    300 x 600
    Weight net/gross
    kg
    630/830
    2100/2800
    4300/5700
    4700/ 6300
    5100/6800
    5500/7300
    6000/8000
    Electrical connections
    V /Hz /A
    230/50/6
    230/50/6
    230/50/6
    230/50/6
    230/50/6
    230/50/6
    230/50/6
    Comp. air consump./Max. pres.
    Nm3/min /bar
    0,2- 0,3/8
    0,3/0,4/8
    0,4/0,6/8
    0,4/0,65/8
    0,4/0,8/8
    0,5/0,9/8
    0,5/0,9/8