SAX EX

Description:

The principle of construction is exactly the same as the SaX filter, and the size ranges up to SaX 24. This SaX EX filter has explosion protection according to the ATEX Directive. The filter is specially designed for Atex Zone 22 classification with built-in explosion membrane and integrated decompression channel.
The major advantage of this filter is that all safety measures for protection of the piping system in front of the filter, is integrated in this filter.

Application range:

Welding fumes of all sorts. And for explosive, fluidizing and easy flowing types of dust. The filter is also very suitable as the filter part of a central vaccum line.

Special features:

Various forms of construction for in- and outlet. Prepared for explosion suppresive equipment.

DATA
UNIT
6
8
12
16
18
20
24
Airflow min./max
m3/h
2100/6300
2800/8400
4200/12500
5600/16700
6300/18800
7002/20900
8400/25100
Area paper/polyester
m2
139/72
186/96
278/144
371/192
418/216
464/240
557/228
No. of cartridges/type included
6
8
12
16
18
20
24
Dustbin/size
L
yes/50
yes/50
yes/50
yes/50
yes/50
yes/50
yes/50
Low pressure max
Pa
800-1500
800-1500
800-1500
800-1500
800-1500
800-1500
800-1500
Height x Width x Depth
mm
2461x2100x2119
2928x1390x2201
2750×2000
3928×1390
3200×2207
4027×1657
3700×2030
In-/outlet diameter outer
mm
300/250
400/300
400/300
500/400
500/400
600/500
600/500
Weight nett/gross
kg
420/492
468/588
780/972
852/1080
888/1128
1080/1320
1440/1680
Electrical connection
V/Hz/A
230/50/6
230/50/6
230/50/6
230/50/6
230/50/6
230/50/6
230/50/6
Comp. air consumption/max pressure
Nm3/min/bar
0,1-0,2/5
0,2-0,3/5
0,2-0,4/5
0,4-0,6/5
0,4-0,7/5
0,5-0,8/5
0,5-0,9/5
Pressure drop over the filter
Pa
800 - 1500
800 - 1500
800 - 1500
800 - 1500
800 - 1500
800 - 1500
800 - 1500

Incl. earth wire and standard controller
Standard colour RAL 5010 Corr. class C2/i
CE Marked